Gina Vasile Scaeteanu, Roxana Maria Madjar
Abstract:
The aim of the research was to evaluate the quality of drinking water from five
private wells (W1 -W5) located in Negresti-Cobadin, Constanta County, Romania.
The evaluation consisted in determination of some specific parameters as pH,
electrical conductivity (EC), total hardness (TH), ammonium, nitrate and nitrite
concentrations and oxidisability index. The results were compared with quality
standards for drinking water imposed by Council Directive 98/83/EC and also with
Romanian legislation. The pH, EC, nitrite and ammonium levels for all water
samples are within recommended ranges. The TH values are higher and range
between 27.41 and 47.14 mg CaO/L. Concerning nitrate levels, it is noteworthy to
mention that excepting W4 sampling point, all water samples exceeded (as average)
maximum admitted level. Oxidisability parameter indicates for wells W1 -W4 values
were below 5 mg O2/L, meanwhile in the case of W5 found value exceeded slightly
limit value.